Two months of real work
Your AC here only runs July and August, with afternoon highs averaging 79°F. It spends the other ten months sitting idle, never pushing against heat the way units do further south.

Takes about a minute. No obligation.
Your AC here only runs July and August, with afternoon highs averaging 79°F. It spends the other ten months sitting idle, never pushing against heat the way units do further south.
A compressor that only runs two months a year still has refrigerant levels, electrical connections and a condenser coil that can drift out of shape over a winter of sitting unused. When something goes wrong on a system like this, age or a part that was never checked is the usual reason, not overwork.

NOAA nClimDiv, 1991–2020 normals
July is when cooling starts here, and it starts at full demand.
Book the check in June, before the first hot day asks anything of it.




Between visits, the filter is the one thing worth your attention. A dirty filter chokes airflow across the coil, and the coil can ice over even on a mild afternoon. Check it monthly while the system is running and swap it when it looks gray or matted. Outside, keep the condenser clear of leaves, grass clippings and anything piled against the cabinet, since it needs open air on all sides to shed heat. Skip the rest. Refrigerant charge, electrical connections and the condition of the coil fins are a tech's job, not something to open up yourself.
A system that only runs two months a year still needs its refrigerant level, connections and coil checked once a season. June, before the first hot day, is the right time to get it done.
Find a contractor
A clogged filter is the one that causes the most trouble, because everything downstream depends on airflow across the coil. Slow that air down and the coil runs colder than it should, cold enough to ice over even when the thermostat says the system is working fine. Ice on the coil blocks more air behind it, and the compressor keeps running against a coil that can't absorb heat the way it's supposed to. That's wear the system didn't need to take on. The condensate drain causes a different kind of trouble. Water coming off the coil has to leave through that line, and algae or dirt will narrow it until the water backs up into the drain pan instead. A dirty coil can still cool a house, just not as well. A blocked drain won't stay contained, it ends up on the floor or the ceiling below, wherever that pan happens to sit.
A squeal when the system starts, a rattle from the outdoor unit, a hum that never turns into a running compressor. These usually mean a belt, bearing or capacitor is wearing out. They tend to get worse slowly enough that you stop noticing, until a neighbor asks about the noise.
The air coming out feels weaker than it used to, or one room never cools down while the rest of the house does. Something upstream is restricting it, maybe a failing blower motor, a duct coming loose, a coil already partway iced. Wait on it and the compressor keeps running against that restriction until something gives.
A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.
A tune-up is the one time someone actually opens the cabinet and checks the things you can't see from the yard. The tech checks refrigerant level against what the system is supposed to hold, since too little means it's leaking somewhere and too much strains the compressor either way. Electrical connections get tightened, because a loose one heats up, and a connection that runs hot long enough eventually fails at the worst time. The capacitor gets tested, not just looked at, since a weak one can still start the compressor on a cool day and fail the first time it really has to work. The coil gets inspected for bent fins and a close look at how clean it actually is underneath the dust you can see. The condensate drain gets cleared before it's clogged, not after it's already backed up into the pan. None of this takes long, and none of it is guesswork. It's the difference between a system that's actually sound and one that's just running for now.